Leppington Building
Inspections

Ducting that was left resting on the ceiling

Crushed duct moves a fraction of the air it was sized for.

Owner Inspections · Leppington 2179 · 2026-04-10

In short: Ducts not suspended on a Leppington lock-up inspection.

How it should sit

Flexible ducting is suspended from the roof structure so it runs in a smooth line with its full cross section open.

What we recorded

Ducting resting directly on the ceiling frame on a Leppington job, rather than suspended.

What happens

The duct crushes under its own weight and the insulation around it, the cross section closes and the airflow drops.

How it shows up

A room that never reaches temperature, months after you move in, with the cause above a finished ceiling.

Why lock-up is the moment

After the linings go up the run is inaccessible without cutting the ceiling open.

Written by the Owner Inspections team from inspections carried out in Leppington. Licensed building practitioners, NSW Fair Trading licence 366177C.

Guides

More defect reports guides for Leppington

All guides →

Book a building inspection in Leppington

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Leppington owners ask about this

Is it a defect or poor practice?

It is a departure from the installation requirements for the system, and the report cites it on that basis.

Could I diagnose it later?

Only by getting into the roof space and tracing the run, which most owners will not do until something is obviously wrong.

Is it expensive to fix?

At lock-up, no. Suspending the run properly is straightforward while the space is open.

Who is responsible?

The builder, through the mechanical contractor who installed it.